    iWave 230i MV AC / DC Parts FAQs

    Torches, torch heads, remote controls, earth leads and trolleys for a multi-voltage AC/DC TIG inverter: how to pick the right part and look after it.

    What checks should I make on the torch, leads and remote control before welding?icon-minus-redicon-plus-red

    The welder is responsible for daily equipment checks and reporting defects. Look at the insulation on the torch, cables, plugs and clamps for cuts, burns or crushing, check that connectors are clean and undamaged, and check the pedal or hand control cable.

    Do not use anything with damaged insulation or loose, hot connectors. A damaged cable should be replaced by a competent person rather than repaired with insulating tape, and kit you are unsure about should be taken out of use. Switch off and unplug the machine before inspecting plugs or changing torch parts.

    Does the length or coiling of welding leads matter?icon-minus-redicon-plus-red

    Yes. Long or undersized leads add resistance and voltage drop, so keep the return lead only as long as you need and use a larger cable size for long runs. Remember the current travels out and back, so the whole circuit is the work lead and the torch lead together.

    Do not coil surplus cable tightly, particularly at high current, because a tight coil cannot shed heat as well as a cable laid out and the insulation can overheat. Lay leads out loosely where you can, and avoid winding them around a trolley or gas cylinder.

    Which tungsten should I use for AC and DC, and what about thoriated types?icon-minus-redicon-plus-red

    Ceriated and lanthanated tungsten are common choices for both DC and AC welding, and the best type depends on your machine and work. Your machine's manual and the tungsten supplier's data will tell you what suits your work.

    Thoriated tungsten contains a slightly radioactive oxide. Grinding is the main hazard because it releases fine dust that can be breathed in. Use a dedicated grinder with local dust extraction, wear a filter mask, collect and seal the dust, and consider whether thoriated electrodes are justified over the alternatives. Make sure your risk assessment covers grinding.

    Should I choose a gas-cooled or water-cooled torch for AC and DC TIG?icon-minus-redicon-plus-red

    Gas-cooled torches are cooled by the shielding gas and cable. They are lighter and simpler, and they usually suit lower current and shorter welds. Water-cooled torches have extra hoses and need a separate cooling unit, but they generally carry more current for longer without overheating.

    Base your choice on the highest current you will weld at, how long you weld without a break, and whether the machine has a cooler connection. Torch ratings are normally quoted with a duty cycle, which is the share of a ten-minute period the torch can run at that current, so compare the figure for the current you will really use. The rating can also differ between AC and DC, so keep within the maker's limits.