    Get reliable protection and comfort while welding or cutting. Zeta Fresh Air is a complete respiratory protection system that combines a lightweight welding and cutting helmet with a certified Kemppi respirator. It puts welder health first with comprehensive eye, face, and respiratory protection, while staying comfortable and easy to use.

    The Zeta Fresh Air W201x features built-in LED work lights that automatically adjust to ambient light. Powered by the blower unit’s battery, the lights can also be controlled manually. The W201x comes with a PFU 210e powered filter unit that blocks 99.8% of harmful fumes, gases, and particles, providing certified TH3-level respiratory protection for maximum on-site safety.

    With their lightweight, narrow design, Zeta Fresh Air welding helmets help reduce neck fatigue and make it easier to move around on-site, while providing EN 166 and EN 175 face protection. Designed for comfort and one-handed use, they also offer complete protection from ultraviolet light and infrared radiation.


    Related Items

    Zeta Fresh Air W201X w/ PFU PAPR Parts FAQs

    Spares for a powered air welding helmet system: how to pick the right part, what wears, and how to keep the system working as intended.

    How do I work out which spare part my powered air helmet system needs?icon-minus-redicon-plus-red

    Start with the data plate or label on the blower unit and helmet, then match what you find to the parts list in the user manual. The part number or marking on the old part is also a useful check, as is the type of filter fitted.

    Use the exact identifiers from your own equipment rather than guessing from appearance, because parts that look alike can differ in fit or performance. HSE guidance advises that replacement parts ideally come from the original manufacturer, so the equipment keeps working as it was approved to do. If you cannot match a part with confidence, ask before ordering.

    Can I use a particle filter against gases or vapours?icon-minus-redicon-plus-red

    No. A particle filter only removes solid and liquid particles such as welding fume and dust. It does not protect against gases or vapours, and a gas or vapour filter alone does not protect against particles. HSE guidance says never to use a particle-only filter against gas or vapour.

    If your work may expose you to gases, for example from certain coatings, cleaning solvents or shielding gases in a confined space, the right filter type and whether a powered filter unit is suitable at all should come from your risk assessment and the manufacturer, not from guesswork. Check what the filter markings say it protects against before you order a replacement.

    How do I check the airflow before I start welding?icon-minus-redicon-plus-red

    Make an airflow check part of every pre-use check. HSE guidance says to check the fan is giving enough airflow before use, to confirm hoses are connected properly and to make sure battery-powered equipment is fully charged. Most makers describe a specific test, often using a flow indicator or by briefly covering the outlet to trigger the warning, so follow the method in your own manual.

    If the unit shows low flow, a blocked or loaded filter, a loose hose or a weak battery are the usual places to look. Do not start work until the unit passes.

    What should I do if the fan stops or the low airflow alarm sounds?icon-minus-redicon-plus-red

    Treat it as a stop signal. HSE guidance says never to keep working if the fan stops or the airflow rate drops, and to leave the work area immediately. Once you are out of the fume, look for the cause: a clogged or damaged filter, a kinked or disconnected hose, or a flat battery are the usual suspects.

    Only return to work when the system is giving the airflow the manufacturer specifies. If you cannot find a simple fix, withdraw the unit from use and have it checked by a competent person rather than carrying on with it.