Kemppi Zeta LED Light Battery Unit
SP022617

£42.09  EX VAT
SSP Suggested Selling Price = £49.52  YOU SAVE £7.43
 Buy in 3 easy interest free payments of £14.03† with

Zeta Fresh Air G201X w/ PFU PAPR Parts FAQs

Answers on the filters, battery parts, headgear and other spares for a powered air respirator used with a welding helmet, and how to pick the right ones.

How do I work out the right replacement filter or spare for my unit?icon-minus-redicon-plus-red

Start with the data plate or label on the blower unit, the parts list in the manual and the markings printed on the old part. Match the type and class markings, not just the way the part looks or fits.

The HSE advises that replacement parts should ideally come from the original manufacturer of the equipment, so it keeps working as originally intended and gives the protection the maker states. A part that fits physically may not be approved for your unit. If you cannot read the markings, our team can help you identify the part.

When should I change the particle filter in my powered respirator?icon-minus-redicon-plus-red

Filters have a limited capacity and can clog, so the HSE says replaceable filters should be changed when necessary. For powered hood and helmet filters it says to change them as the manufacturer instructs, so there is no single interval that suits every unit.

Typical signs include a filter or low-airflow alarm, an indicator, a shorter battery run time, or visible damage or wetness. Check your manual for the signs on your unit. Never keep working if the fan stops or the airflow falls: leave the work area and sort the problem out first.

How do I check the airflow, and why does it matter?icon-minus-redicon-plus-red

A powered helmet protects you by blowing enough clean air across your face to keep contaminated air out. If the airflow drops, that protection drops with it.

The HSE lists checking battery charge and flow rate as a key maintenance task for powered devices, and says to leave the work area at once if the fan stops or the flow falls. Most units have a flow meter or indicator, or an alarm, so use the method in your manual, with a fully charged battery and a clean, correctly fitted filter, before each use.

Does an odour pre-filter protect me from welding gases?icon-minus-redicon-plus-red

Not on its own. The HSE explains that particle filters do not trap gases or vapours, and gas filters do not protect against particles. Where both are needed, a combined filter marked for both is used.

An odour pre-filter is usually intended to reduce nuisance smells and should not be treated as protection against a gas hazard unless the maker's markings and instructions say so. Whether gas protection is needed depends on your process, materials and risk assessment. Check the markings on the filter and the manual, and ask the maker if in doubt.