MEX operation panel
Answers on identifying, choosing and safely fitting internal and mechanical spares for an inverter welding power source.
Start with the rating plate on the machine. It normally shows the manufacturer, type designation, serial number and the electrical ratings, and this is usually the only reliable record on an older unit. Then use the maker's manual or parts list to find the part and its reference number.If the old part has a number or marking on it, note it, but do not rely on it alone, because the same part can be used in several versions. Photograph the part, the board or the connector before removing it, and quote the plate details when you ask for help.
The control card, or control board, is the electronic board that manages the welding output, settings, display and protection functions. Signs of a fault can include no response when switched on, error indications, unstable or missing output, and settings that do not hold.Many faults that look like a failed board are actually caused by a damaged cable, loose connector, a blown supply fuse or a fault elsewhere, so have the machine checked first. Boards are matched to the machine version, so the replacement should be the same type and revision as the maker specifies for your plate details.
Circuit boards can be damaged by static electricity that you cannot feel. Keep the new board in its anti-static bag until you are ready to fit it, and ground yourself before touching it, ideally with a wrist strap, as service guidance for electronic boards advises.Handle it by the edges, avoid touching components and connectors, and put the old board straight into an anti-static bag. Only work on the machine once it is isolated from the mains and any stored energy has been dealt with, following the maker's service instructions.
Power sources of this type can hold stored electrical energy in capacitors for some time after they are switched off and unplugged. Isolating the machine from the mains is not enough on its own.The waiting time and the way of checking that the machine is safe depend on the design, so follow the maker's service instructions rather than a general rule of thumb. This kind of work should be done only by a competent person, since mistakes can cause fatal electric shock.